Index > News > Technical articles > Is the water speed of the ultrapure water machine slowing down? Don't worry, there is a coup!
With the development of science, technology and economy, the market in all walks of life is constantly expanding, and the same is true for ultrapure water machines, and in order to meet the needs of the market, it is constantly developing and innovating. An ultra-pure water supply system to meet the water needs of various industries such as inspection and analysis. However, with the long-term use of the ultra-pure water machine, the equipment will gradually have some small faults, and the water production may become slow. Many users are helpless in this situation. Next, I will introduce the solution to the slow water speed:
1. The transformer is faulty
If the transformer fails, it cannot provide the normal required voltage, the speed becomes slower, and the boost pressure becomes smaller. Naturally, the pressure required for the tap water to pass through the RO membrane will not be reached, and the water speed will become slower. In fact, after excluding the main factors affecting slow water production such as pumps and membranes, it is necessary to replace a new transformer for testing.
2. The check valve is blocked
Sometimes the check valve will be blocked, which rarely happens, so you can take off the check valve and check the amount of water. If there is a significant change in the water output after cleaning and before, it means that the check valve is really blocked.
3. Clogging of the membrane
If the pre-filter is not cleaned for a long time, the water quality in the machine will deteriorate. Originally poor water quality will cause the blockage of the wastewater solenoid valve or the flushing combination valve, so the wastewater will not be discharged, or the wastewater will be less, which will directly lead to the blockage of the membrane and shorten the service life of the equipment.
4. The pump pressurization is small, and the pump loses pressure
The pump pressurization amount is small, which generally occurs when the equipment has been used for more than two years or when the equipment has been working for a long time. Pump pressure loss is generally not easy to find. It is directly manifested as little or no membrane water, which is often mistaken for membrane blockage.
Generally speaking, if the production speed of the equipment is slow, it is caused by these factors, and the operator can find the cause of the problem and then solve the problem. Only by ensuring the normal use of the equipment can we bring the conditions for efficient operation to the production work of the enterprise.
5. The filter element is blocked
Clogging of the filter element is one of the common faults. The pollution of tap water is becoming more and more serious. If you catch up with the maintenance of the pipeline, it can be said that the filter element must be blocked. Replacing the filter element is a key factor to prolong the life of the equipment, and personnel should be arranged to maintain and replace it on a regular basis to ensure that it is unobstructed.
The above are the techniques that can effectively solve the slowdown of the water speed of the ultrapure water machine. Users can use these methods to solve this situation, which can not only save time and cost, but also reduce the economic cost of users.
About us
Company profileHonorary qualificationEnterprise dynamicsTechnical articlesProduct display
Laboratory and medical sewage treatment system Water system of laboratory science and Education Institute Water system for pharmaceutical industryColumn navigation
Product Center Project case Video Center Service supportContact us
Online MessageContact uscopyright © 2022 Nanjing Yipu Yida Technology Development Co., Ltd Al Rights Reseved Record number:苏ICP备19073731号-1 Sitemap.xml Manage login technical support:Chemical Industry Instrument Website