Standardized operation makes laboratory ultrapure water device effective

Release time:2021-01-20    Views:1835

       The laboratory ultra-pure water device is an ultra-pure water supply system designed for industrial water demand to meet the working water requirements of various industries such as inspection and analysis. Its practical application is very many industries. , Large-scale circuit components, chip packaging and liquid crystal manufacturing. Photoelectrochemistry in chemical industry, daily chemical product manufacturing, thermoelectric chemical industry, metallurgy, textile printing and dyeing, light industry manufacturing, fine chemicals, automobile manufacturing and other manufacturing industries. Ultrapure water is commonly used.

In order to ensure that the use of the laboratory ultrapure water device can achieve the expected effect, the operator needs to operate it according to the correct method. Let us share some experiences below.

How to use the laboratory ultrapure water device:

1. Before using the instrument, please read the product instruction manual carefully to understand the precautions and safety tips.

2. A comprehensive inspection should be carried out before installation to observe whether the instrument placed on the flat workbench has a complete appearance, the plug is intact, and the power switch is flexible. And check whether the power socket of the instrument is reliably grounded to ensure the safety during operation.

3. When using, first open the ball valve, turn on the power supply, and ensure that both the water source and the power supply are connected.

4. Observe whether there is leakage in the ultrapure water machine. If there is leakage, turn off the power supply and water ball valve in time to make adjustments.

5. If everything is normal, turn on the power switch after 10-20 seconds.

6. When taking pure water, lightly press the water taking button to take water easily. You can choose one of the water quality according to the actual needs of the dual-flow outlet of the U-Pure ultra-pure water machine.

7. The purification column can be loaded or replaced only when the power is off or the power switch is turned off, and the specifications and models of the column can be checked before the replacement is in line with the performance requirements of the machine.

8. The installation environment of the instrument should ensure that the temperature is not higher than 40 degrees in summer and higher than 4 degrees in winter. To avoid irreversible damage to the instrument.

9. The instrument is rinsed for 10 minutes under the condition that the water inlet pressure is less than 0.4MPa each time it is started or stopped.

10. When the laboratory ultrapure water machine is not used for a long time, all power sources and switches should be turned off.