      The ultra-pure water machine adopts pretreatment, reverse osmosis technology, ultra-purification treatment and post-treatment methods to almost completely remove the conductive medium in the water, and remove the non-dissociated colloidal substances, gases and organic substances in the water to a very low degree. water treatment equipment. The resistivity of ultrapure water it produces should generally be greater than 10 megohms, and water above 10 megohms is called ultrapure water. In order to ensure its normal use, it is not only necessary to use it correctly, but also to pay great attention to its installation and storage. Let's take a closer look at the conditions that need to be met for its installation and storage.

1. The best working temperature is 5~45℃, and the installation and use conditions are as follows:

1. If the ultrapure water machine is installed outdoors:

When the ambient temperature is lower than 5°C, please turn it off in time and move it to a suitable place for indoor temperature.

When the ambient temperature is lower than 0 ℃, it is strictly prohibited to use. The volume of water will expand during the solidification process. If it freezes, it will directly cause the pipeline, filter element, membrane shell, etc. to burst, resulting in water leakage.

If you suspend use, please close the water inlet valve, drain all the water in the whole machine, water tank and filter element as much as possible, and move the machine indoors.

2. If the ultrapure water machine is installed indoors:

When the ambient temperature is lower than 5 ℃, please turn on the heating, air conditioning and other equipment in time, and take antifreeze measures.

When the equipment runs at abnormal working temperature, there will be failures such as filter element blockage, poor filtering effect, unstable water output, and wrong instrument display, so please make preparations and work for antifreeze in time to avoid unnecessary losses.

2. In the event of suspension of use, the storage conditions are as follows:

1. Cut off the water and power supply.

2. Drain all the water inside the equipment and in the water tank.

3. Store in an environment not lower than 5°C.

4. If the storage temperature cannot be met, please use foam cotton and other materials on the outside of the equipment for insulation.

WeChat official account