       The laboratory sewage treatment device is very popular in the treatment of laboratory sewage, because its treatment method is targeted, and the corresponding treatment technology and control system can be used for sewage treatment according to the composition of different experimental sewage. The sewage treated by this device meets the first, second and third standards in the comprehensive discharge standard [GB8978-1996], so that the treated sewage can be discharged into the municipal sewage pipe network, and can also be treated by the reprocessing process. The waste water is reused.

The debugging work before the official use of the laboratory sewage treatment device is essential. Let's share some debugging tips to help you make better use of the equipment.

1. Inspection work before commissioning:

1. The idling point is turned on and off the fan, the water pump rotates and operates, and the operation reliability of the electric control cabinet components.

2. Check the lubrication oil filling of the fan in the equipment room.

3. Check the firmness of the internal and external pipeline connections.

4. Check the connection of internal and external circuits.

5. Inject sewage into the buried integrated sewage treatment equipment, and check whether there is leakage at the joints of each pipeline.

6. Start the fan, check the operation of all equipment in the domestic sewage plant, whether there is abnormal vibration, noise, etc.

2. Debugging steps:

1. Fill the contact biochemical tank with clean water.

2. Start the fan to aerate and oxygenate the sewage in the pool.

3. Re-enter the water and continue to aerate.

4. Repeated operation like this will prolong the water intake time every day.

5. At the same time, it is also possible to observe the contact with the filler in the biological pool.

6. The domestication of microorganisms takes a long time, which can accelerate the formation of biofilms.

Debugging the laboratory sewage treatment device before use according to the above method will help to better use the product and make it achieve the desired effect.